RAM T-1208 Instrukcja Obsługi Strona 9

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 20
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 8
DX1208 – 9
The DX1208 can also be connected to a PC via the Ethernet
port, provided the PC has an Ethernet port as well. Use a Cat5
or Cat5e Ethernet cable with RJ-45 connectors.
Note: Use a Cat5 or Cat5e crossover cable when
connecting the DX1208 directly to a PC. If you are connecting
through an Ethernet switch, use a straight-through cable.
L a p t o p
C o m p u t e r
8
S/P D I F
9 / 1 0
1 1 / 12
7 6 5
LOGIC
3OU T 2OU T 1O U T 6IN 5IN 4I N 3IN 2I N 1I N ININININ
ININININ
4 3 2 1
8 7 6 5
DX 1208
INI NININ
R
L
R
L
R
L
IN
IN
ADDRESS
ETHERNET
RS232
ANA L O G
OUT P U T
D C B AH G F E
DX LINK RX
DX LINK TX
REMOTES
ON
100-240VAC 50-60Hz 40W
Ethernet connection
An RS-232C serial port is also available for connecting
a PC or other controller. This is a DB9 female connector on
the DX1208 rear panel and requires a cable with a DB9 male
connector on the DX1208 end. The DX1208 is configured as a
device or Data Communications Equipment (DCE), which is to
be connected to a controller or Data Terminal Equipment (DTE)
and be controlled.
L a p t o p
C o m p u t e r
o r O t h e r C o n t r o l l e r
8
S/P D I F
9 / 1 0
1 1 / 12
7 6 5
LOGIC
3OU T 2OUT 1O U T 6I N 5IN 4I N 3IN 2I N 1I N ININININ
ININININ
4 3 2 1
8 7 6 5
DX 1208
INI NININ
R
L
R
L
R
L
IN
IN
ADDRESS
ETHERNET
RS232
ANA L O G
OUT P U T
D C B AH G F E
DX LINK RX
DX LINK TX
REMOTES
ON
100-240VAC 50-60Hz 40W
RS232 connection
A separate document is available that provides information
on port settings and control protocol for the RS-232
connection.Visitwww.eaw.comformoreinformation.
Connecting the DX LINK RX/TX
These two RJ-45 connectors are provided to connect DX
Link enabled devices together and transfer audio among the
devices. Up to 16 channels of audio can be transmitted over
the DX link ring network using shielded CAT5 cable, and up to
8 DX Link devices can be connected together.
When two or more DX1208s are connected together using
DX Link, one must be configured as a Master and the rest as
Slaves. This is done in the Settings window of DX Navigator,
and the audio is managed in the DXLink window.
Note: Although the DX Link uses Cat5 or Cat5e network
cable, this is not “audio over Ethernet” and cannot use
standard network hardware such as switches or repeaters.
Connect the TX connector on the master device to the RX
connector on the first slave device. Then connect the TX on the
slave to the RX on the next slave, and so on. Connect the TX
on the last slave back to the RX on the master to complete the
connection.
M a s t e r
8
S/P D I F
9 / 1 0
1 1 / 12
7 6 5
LOGIC
3OU T 2OUT 1O U T 6I N 5IN 4I N 3IN 2I N 1I N ININININ
ININININ
4 3 2 1
8 7 6 5
DX 1208
INI NININ
R
L
R
L
R
L
IN
IN
ADDRESS
ETHERNET
RS232
ANA L O G
OUT P U T
D C B AH G F E
DX LINK RX
DX LINK TX
REMOTES
ON
100-240VAC 50-60Hz 40W
S l a v e
8
S/P D I F
9 / 1 0
1 1 / 12
7 6 5
LOGIC
3OU T 2OUT 1O U T 6I N 5IN 4I N 3IN 2I N 1I N ININININ
ININININ
4 3 2 1
8 7 6 5
DX 1208
INI NININ
R
L
R
L
R
L
IN
IN
ADDRESS
ETHERNET
RS232
ANA L O G
OUT P U T
D C B AH G F E
DX LINK RX
DX LINK TX
REMOTES
ON
100-240VAC 50-60Hz 40W
S l a v e
8
S/P D I F
9 / 1 0
1 1 / 12
7 6 5
LOGIC
3OU T 2OUT 1O U T 6I N 5IN 4I N 3IN 2I N 1I N ININININ
ININININ
4 3 2 1
8 7 6 5
DX 1208
INI NININ
R
L
R
L
R
L
IN
IN
ADDRESS
ETHERNET
RS232
ANA L O G
OUT P U T
D C B AH G F E
DX LINK RX
DX LINK TX
REMOTES
ON
100-240VAC 50-60Hz 40W
DX LINK connection
Connecting the REMOTES
An RJ-25 connector on the rear panel is used to connect
the optional remote control peripherals. You can connect
up to 10 remotes on the remote bus. More remotes can be
connected to the remote bus, provided that external power is
supplied to the additional remotes. Refer to the documentation
provided with the remote control units for more information.
There are currently two types of remote controls available
for the DX1208. Each remote has two RJ-25 connectors, one
for connecting the remote bus from the previous device and the
other for connecting to the next device. Each remote also has
an eight position DIP-switch for assigning its unique address.
Przeglądanie stron 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 19 20

Komentarze do niniejszej Instrukcji

Brak uwag